Nothing is more frustrating than having to invest in a costly appliance repair on a sweltering summer day. When your Goodman AC condenser’s fan motor breaks, the last thing you want to do is pay hundreds of dollars for a professional to come out and replace it. Although it may not seem like a task for the faint-of-heart, replacing the fan motor in your Goodman air conditioning system is not as complicated as it sounds and can be done by nearly anybody with basic DIY skills. Here is a simple guide for how to replace the fan motor in your Goodman AC condenser on your own, potentially saving you money on costly professional services.
Understand the Parts
Before even attempting repair, it is important to first understand some of the most essential parts of your Goodman AC condenser’s fan motor assembly. The fan motor itself is the primary component and is responsible for spinning the condenser fan blades that help your unit’s air to be cooled faster. The motor is held by the fan motor bracket, and connected by the fan motor wires. In addition, the fan motor relies on the capacitor to help start and provide the fan motor with energy.
Disconnect Power and Shut Off the Unit
Whenever attempting to repair, replace or handle any AC condenser fan motor or components connected to the fan motor, it is essential to completely shut off the unit and disconnect the power. This can be done by simply unplugging the unit from the wall to completely shut off the power, or if the unit is hardwired, turning the breaker off. Once the power has been disconnected, wait for a few minutes for the system to discharge any remaining electricity. If a professional is hired to handle the repair, ask them to ensure the power is completely shut off and disconnected from the system before they start working.
Fan Motor Assembly Removal
Once the power has been disconnected, the fan motor assembly will need to be removed. To do this, first remove the screws connecting the motor bracket to the Goodman AC condenser housing, carefully supporting the fan motor as it is removed, and disconnect the fan motor wires connected to the fan motor. Before placing the assembly out of the way, you should write down the color coding of each fan motor wire, as well as labeling each wire. If a capacitor is connected to the fan motor, unplug it and store it safely.
Install the New Fan Motor
Now with the old fan motor assembly out of the way and the new fan motor in hand, it is time to install it. Begin by connecting the fan motor wires to the color-coded slots, ensuring that all wires are securely connected. Next, connect the fan motor to the fan motor bracket, being careful to not over-tighten the screws. Finally, if the old capacitor is in working condition, the same capacitor should be re-attached. However, if needed, a new capacitor must be purchased in the exact same rating as labeled on the original.
Final Steps
The last step is to reinsert the fan motor assembly back into the Goodman AC condenser housing, ensure all wiring is connected and secure and replace whatever case or panel screws were removed. At this point, the new fan motor is installed and the process is finished. To ensure the repairs were successful, power should be again disconnected and reconnected, wait a few minutes and fire up the unit, double-checking that the fan is spinning properly. Although DIY Goodman AC condenser fan motor replacement may sound overwhelming at first, if you are able to understand the basics and have the right tools, the process does not have to be overly complicated and expensive.
If you have any difficulty in the fan motor installation process, or any other Goodman AC condenser issues related that you are unable to troubleshoot on your own, always make sure to contact a licensed and experienced appliance repair service that specializes in Goodman AC condenser units. Don’t take the risk with inexperienced repair services and always choose certified pros who get the job done correctly with minimal risk. In any case, Local Reliable Appliance Repair (866-311-8590) is at the ready to assist with any and all Goodman AC condenser fan motor replacement needs!



Preventive Actions to Avoid Goodman AC Condenser Fan Motor Replacement Issues
Keeping an air conditioning system running efficiently requires regular maintenance. Goodman AC condenser fan motors are a critical component of any AC system, and preventive actions should be undertaken to avoid costly replacement issues. To ensure the best performance and longevity of the AC condenser fan motor, a homeowner should understand manufacturer recommendations, and the insights of local AC technicians. This article offers advice, best practices and an itemized list of preventive maintenance procedures for Goodman AC condenser fan motor replacement.
Manufacturer Recommendations
Goodman AC condenser fan motor replacement should only be handled by a certified Goodman servicing dealer or AC technician. Before replacing the motor and fan, the technician should contact the authorized Goodman dealer for technical service.
The manufacturer offers a few important guidelines to ensure proper installation and usage of the Goodman AC condenser fan motor. These guidelines include:
- Regularly check the capacitor for failsafe operation
- Replace the fan blades with only genuine Goodman parts if they are damaged
- Ensure the fan motor is the properly rated horsepower
- Avoid storing and installing the fan motor in an excessively hot, humid or wet location
Local Appliance Companies’ or HVAC Technician’s Recommendations
Local AC and heating companies, as well as experienced HVAC technicians, offer useful advice on Goodman AC condenser fan motor replacement. They recommend a few common sense actions that can help avoid costly repairs and replacements. These preventive measures include:
- Clean the exterior cabinet, fins and fan motor regularly
- Change out the condenser fan motor’s capacitor annually
- Make sure the motor is properly sized for the AC unit and that the fan blades spin without disruption
- Check the fan belt for any signs of wear and tear, and replace if needed
- Monitor the AC drain line for proper drainage
Professional servicing or maintenance of an AC system is highly recommended to ensure the longest life expectancy. Additionally, technicians or certified professionals should always be used for Goodman AC condenser fan motor replacement.
Itemized List for Preventive Maintenance
To ensure the best performance and life expectancy for the Goodman AC condenser fan motor, homeowners should undertake preventive measures to avoid costly repairs and replacements. Here is an itemized list of preventive maintenance procedures to consider:
- Check the capacitor for proper performance
- Use only genuine Goodman parts to replace the fan blades
- Ensure the fan motor is the correct horsepower
- Avoid installing the fan motor in excessively hot locations
- Clean the cabinet, fins and fan motor regularly
- Change the condenser fan motor’s capacitor annually
- Make sure the fan blades spin without disruption
- Check the fan belt for any signs of wear and tear
- Monitor the AC drain line for proper drainage
- Have the system professionally serviced or maintained
By following the suggested preventive maintenance procedures, a homeowner can be assured that their Goodman AC condenser fan motor replacement is handled properly and will last for years to come.
Advice for Goodman AC Condenser Fan Motor Replacement
Replacing a Goodman AC condenser fan motor can be a complex and time consuming task, so it’s important to understand the cost and necessary parts involved. Generally, the minimum repair or installation cost for this issue is around $100-$150, with a complex repair or installation in the California area being closer to $200-$400. Depending on the issue, some of the required components that may be necessary to repair or replace the fan motor include:
- AC condenser
- Replacement fan motor
- Wiring harness
- Electrical wiring
- HVAC technician
- Mounting bracket
In addition to these components, any necessary parts and materials required for the fan motor replacement (such as nuts, bolts, screws, etc.) will be an extra cost to consider.
For the best professional advice on a Goodman AC condenser fan motor replacement, we recommend contacting a local and reliable air conditioning and heating company. We recommend calling Local Reliable Air Conditioning & Heating at (866) 311-8590 to get the best service and advice.
Goodman AC Condenser Fan Motor Replacement
Are you in need of a Goodman AC condenser fan motor replacement? If so, you can rely on California Reliable Air Conditioning & Heating, a family-owned local business, to provide top-notch service.
Reliable’s highly trained technicians have a minimum of 5 years experience, so you can be sure the job will be done right. The company also offers same-day service, meaning you won’t have to wait around forever to get your air conditioner working again.
Reliable Air Conditioning & Heating repairs and installs Goodman AC condenser fan motors on a regular basis, and provides competitive prices. Being a local California business, you can trust that you’re getting a deal that’s fair for everyone.
Your new or repaired Goodman AC condenser fan motor will be covered by a 90-day warranty. The company is licensed and insured, so you can feel confident as Reliable begins working on your air conditioner.
When you’re in need of reliable HVAC repair or installation, trust that California Reliable Air Conditioning & Heating will deliver quality service. Look no further for a reliable Goodman AC condenser fan motor replacement.
FAQ on DIY Goodman AC Condenser Fan Motor Replacement
How to replace Goodman AC condenser fan motor?
Replacing a Goodman AC condenser fan motor is not difficult, but requires proper preparation and certain tools. Start by turning off the power to the unit. Loosen the fan blade screws and gently remove the blade. Inspect the blade for wear and tear and then remove the plastic or metal cover on top of the fan motor. Loosen the four screws securing the fan motor, remove the harness wires, and remove the fan motor from the mounting plate. Attach the replacement fan motor, connect the wiring harness plug, and secure with the four screws. Reinstall the fan blade and re-connect the power and enjoy your new motor!
What tools are required for a Goodman AC condenser fan motor replacement?
The tools required for a Goodman AC condenser fan motor replacement are simple but necessary. You will need a screwdriver, pair of pliers, and adjustable wrench. You may also need a few other tools, depending on the model of the AC condenser unit.
How do I know when the Goodman AC condenser fan motor needs to be replaced?
Before you decide to replace the Goodman AC condenser fan motor, inspect the fan blade to determine if it is wearing out or has sustained any damage. If the fan blade has stopped spinning, is not spinning properly, or if it looks worn out, the motor should be replaced.
Can I replace Goodman AC condenser fan motor myself?
Replacing a Goodman AC condenser fan motor is generally a job for an experienced professional. Without the proper expertise and experience, you can cause damage to both the unit and yourself. It is highly recommended to call a reliable appliance repair service for the proper installation of a Goodman AC condenser motor.
We advise calling Local Reliable Appliance Repair at (866) 311-8590 for any issues related to DIY Goodman AC Condenser Fan Motor Replacement.